The International Society of Automation (ISA) specifies standard ISA 12.13.01 which describes test methods that apply to portable, transportable, and fixed devices for the detection and measurement of flammable gas or vapor concentrations in air. Resources. Operating Principle of Semiconductor Type Gas Sensors. Principles of Gas Detection
DEF STAN 68-83. December 18, 1984. Sulphur. This Standard relates to sulphur for use in explosives and pyrotechnic mixtures. References. This document references: BS 1752 - Laboratory Sintered or Fritted Filters Including Porosity Grading. Published by BSI on December 30, 1983. Covers glass, silica, ceramics, metal or …
Company engineers have focused on sulfur to replace more commonly used and higher cost cathode materials such as nickel and cobalt. Sulfur is 99% cheaper to source than cathode materials used in state-of-the-art lithium-ion batteries, and the new battery cells also require 90% less energy to produce from raw material to finished cell.. …
Description: The PGC1000 is a field-mount gas chromatograph (GC) capable of measurements of C1 through C9+, inerts and H2S in various Hydrocarbon Processing Industry (HPI) streams. This analyzer is perfect for measuring light hydrocarbon gases in locations where minimal space is available. Applications: Energy.
Find Portable Sulfur Analyzer related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of Portable Sulfur Analyzer information.
Grade B6 to B20 S15- A fuel with a maximum of 15 ppm sulfur. Grade B6 to B20 S500- A fuel with a maximum of 500 ppm sulfur. Grade B6 to B20 S5000- A fuel with a maximum of 5000 ppm sulfur. This specification prescribes the required properties of B6 to B20 biodiesel blends at the time and place of delivery. The specification requirements may be ...
This testing device measures the chemicals in the breath; classifies the volatile sulfur compounds, a major component of halitosis, into three causal components (hydrogen …
This method is for determining sulfur in liquid hydrocarbons at concentrations ranging from 10 to 1500 ng/g (mass-ppb). A direct measurement procedure (Part A) is used for samples above 100 ng/g. A trap & release procedure (Part B) is used for samples between 10 and 200 ng/g where high precision is required.
Products/Services for Portable Lube Oil Analyzers. Oil Sensors and Analyzers - (68 companies) Oil sensors and oil analyzers are used in automotive or industrial machinery applications to sense oil levels and to check for contamination, particulates, viscosity, and/or temperature. Oil sensors and oil analyzers are also known as ferrography...
Burkert Fluid Control Systems. Molten Metal Treament Solution: Mass flow controllers for molten metal treatment. B urkert 's mass flow controllers (MFCs) make your gas control processes reproducible. This allows you to set the flow rate of your gases automatically and with a high. level of repeat accuracy.
S. Himmelstein | May 04, 2017. A closed sulfur-sulfuric acid cycle is being developed for large-scale chemical storage of solar power and its overnight use as an energy source. The research is being conducted by Karlsruhe Institute of Technology (KIT), Germany, and partners as part of the EU-funded PEGASUS project.
Supplier: Sauereisen, Inc. Description: Sauereisen Nos. 600 and 610 Sulfur Based Mortars are used in the construction of floors, trenches, sumps and tanks in steel mills, mines, metal finishing and chemical processing plants. They are also used as a capping compound for concrete test cylinders. Applications: Flooring.
EN 14582 - Characterization of waste - Halogen and sulfur content - Oxygen combustion in closed systems and determination methods Published by CEN on August 1, 2016 This standard specifies a combustion method for the determination of halogen and sulfur contents in materials by combustion in a closed system containing oxygen (calorimetric …
OC-906 portable pump-suction gas detector used to inspect the single gas concentration. Suitable for the environmental monitor, industrial production, and other working place …
ASTM B809 - Standard Test Method for Porosity in Metallic Coatings by Humid Sulfur Vapor ("Flowers-of-Sulfur") Published by ASTM on October 10, 1995 This standard covers equipment and test methods for determining the porosity of metallic coatings, where the pores penetrate down to a silver, copper, or copper-alloy substrate.
Introduction. The impressive theoretical energy density (2600 Wh kg −1) and high theoretical capacities (1675 mAh g −1), combined with the low cost of sulfur and its …
Find the most up-to-date version of ISO 7269 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... RUBBER - DETERMINATION OF FREE SULFUR active, Most Current Buy Now. Details. History. Organization: ISO: Status: active: Page Count: 14: Document History. ISO 7269
The fuel sulfur grades are described as follows: Grade B6 to B20 S15-A fuel with a maximum of 15 ppm sulfur. Grade B6 to B20 S500-A fuel with a maximum of 500 ppm sulfur. Grade B6 to B20 S5000-A fuel with a maximum of 5000 ppm sulfur. This specification prescribes the required properties of B6 to B20 biodiesel blends at the time …
Description: P/N 04810-0500, Spectrum Series Personal Gas Detector for Sulfur Dioxide, SO2 The SPECTRUM Series portable gas detector is a compact, durable and …
Find the most up-to-date version of ASTM D129-00 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... 1.1 This test method covers the determination of sulfur in petroleum products, including lubricating oils containing additives, additive concentrates, and …
The most powerful, accurate portable refrigerant detector. 1 ppm Minimum Detectable Level. Detect leaks that other instruments can 't. Cut leak inspection times.
Find the most up-to-date version of ISO 19739 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... This test method is for on-line measurement of gas phase sulfur-containing compounds in gaseous fuels by gas chromatography (GC) and electrochemical (EC) detection. This …
Oil Sensors and Analyzers Information. Oil sensors and oil analyzers are used in automotive or industrial machinery applications to sense oil levels and to check for contamination, particulates, viscosity, and/or temperature. Oil sensors and oil analyzers are also known as ferrography instruments. Ferrography is a method of wear analysis that ...
UV Lamps Information. Ultraviolet (UV) lamps emit electromagnetic radiation with a wavelength between 10 nanometers (nm) and 400 nm, which is below the visible light spectrum. UV lamps have industrial uses in sterilization, geology, polymer and adhesive curing, and laboratory research and analysis, including biological analysis.
This document specifies a method for the extraction of the total sulfur contained in fertilizers in elemental form and/or in other chemical combinations. The method is applicable to EC fertilizers for which a declaration of the total sulfur present in various forms (elemental, thiosulfate, sulfite, sulfate) is provided. Document History.
Find the most up-to-date version of F852/F852M at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... but a specification for portable gasoline, kerosene, and diesel containers for consumer use. ... No. 1-K—A special low-sulfur grade kerosine suitable for use in nonflue-connected …
scope: This European Standard specifies methods for the determination of the total sulfur and total chlorine content in solid biofuels. The standard specifies two methods for digestion of the fuel and different analytical techniques for the quantification of the elements in the digest solutions. The use of automatic equipment is also included ...
ASTM International - ASTM D7058-04(2014) Standard Test Method for Determination of the Red Dye Concentration and Estimation of Saybolt Color of Aviation Turbine Fuels and Kerosine Using a Portable Visible Spectrophotometer
from Nova Analytical Systems Inc. The Model 309 Series Portable CO2 and O2 Analyzer is a rugged, fast-responding, and accurate instrument for conveniently monitoring the atmosphere in a fruit storage C/A room. The standard range of the analyzer is 0-10% CO2 and 0-25% O2. Other ranges are available.
scope: This document defines the quality for technical grade sulphur hexafluoride (SF 6) and complementary gases such as nitrogen (N 2) and carbon tetra-fluoride (CF 4), for use in electrical equipment.Detection techniques, covering both laboratory and in-situ portable instrumentation, applicable to the analysis of SF 6, N 2 and CF 4 gases prior to the …